Networking and Telecommunications - Missouri State University Information Services Missouri State University Networking and Telecommunications
Skip search and site index

Door Wiring Diagrams

This is an index page to some of the detailed wiring diagrams created by Networking and Telecommunications with initial assistance from Tech Electronics, who has a very knowledge and personable staff.  If a diagram is not found that exactly addresses the type of door and the exact set of features present, please contact Steven Coffman and a custom diagram will be created specifically designed for any door.  All new diagrams will be posted here.  Diagrams for the following doors are currently available:


Drawings and Features:

Thumbnail:  PDF Link File Name Door Description Required and Recommended Features
Door Access 6 wiring diagram Door Access 6 Double doors, two active panels, ADA openers, smoke evacuation, and one credential reader. Request to Exit switches on the Panic Devices, Door Position Switches, Lock-out Relay, Auxiliary Power Supply, Power Transfers, Electronic Mortice Locks, Door Openers, Connection to Smoke Evacuation Controller, Card Reader, Push Paddles (inside and out), and optional Dog Position Switchs.  A Latch Bolt Monitor is highly suggested, but not required.
Door access 8 wiring diagram Door Access 8 Single door, active panel, and one credential reader. Request to Exit switches on the Panic Device, Door Position Switches, Power Transfer, Electronic Mortice Lock, and a Card Reader.
Door access 9 wiring diagram Door Access 9 Double doors, one active and one passive but monitored panel, locking rods, and one credential reader. Request to Exit switches on the Panic Device, Door Position Switches, Power Transfers, Electric Lock, and Auxiliary Power Supply.  Optional Dog Position Switches and Rod Position Monitor switches are hightly suggested, but not required.
Door access 10 wiring diagram Door Access 10 Double doors, with both panels active and monitored, locking rods, and one credential reader. Request to Exit switches on the Panic Device, Door Position Switches, Power Transfers, Electric Locks, and Auxiliary Power Supply.  Optional Dog Position Switches and Rod Position Monitor switches are hightly suggested, but not required.